Brandon & Christian

June 2026

AC Won't Cool Past 76 Degrees in Seabrook

What the customer reported

A Seabrook homeowner reported that their air conditioner was not cooling past 76.

What we found and did

Brandon and Christian found a crack in the suction line outside and the unit grossly undercharged. They recovered the remaining refrigerant, repaired the leak on the suction line, and replaced the filter drier. The team then nitrogen pressure tested the system to 340 psi and performed a triple evacuation to reach an ultimate vacuum of 315 microns.

Result

The system was recharged with 6 lbs of R-410A to reach proper levels.

AC Won't Cool Past 76 Degrees in SeabrookDuring
Brandon and Christian found a crack in the suction line outside and the unit grossly undercharged.
AC Won't Cool Past 76 Degrees in SeabrookAfter
Brandon and Christian found a crack in the suction line outside and the unit grossly undercharged.
Explore more

Related services and areas

More ways we can help in Seabrook.

FAQ

Refrigerant Services in Seabrook: questions answered

Answered by our licensed technicians serving Seabrook.

Why is my AC blowing warm air if it's not low on refrigerant?

Salt corrosion on condenser coils can reduce heat transfer enough that your system runs continuously without reaching set temperature, even with a full refrigerant charge. If the aluminum fins are pitted, caked with salt deposits, or crumbling, the coil can't reject heat efficiently regardless of refrigerant level.

How do you find refrigerant leaks that other companies can't?

We use three methods: electronic leak detectors that sense concentrations as low as 0.1 oz/year, nitrogen pressure testing at 300-400 PSI to isolate which section is compromised, and UV dye injection for microscopic leaks. Most companies only use one method. We use all three because coastal pinhole leaks are harder to find.

Should I just top off my refrigerant?

No. Adding refrigerant without fixing the leak is like putting air in a tire with a nail. On the coast, the salt corrosion that caused the first leak is actively creating new ones. You'll need another recharge in weeks or months, at $50-$150/lb for R-410A or $150-$300/lb for R-22.

My system uses R-22. What are my options?

R-22 is phased out and increasingly expensive. If your system needs refrigerant more than once per season, replacement with a new R-410A or R-454B system is the better investment. Two R-22 recharges can cost $1,500-$6,000, money that goes further toward new equipment.

Can corroded copper refrigerant lines be repaired or do they need full replacement?

Isolated leaks can be brazed with silver solder and coated. But on coastal systems over 7-8 years old, we often find multiple corroded areas. Repairing three spots only to have new leaks open in six months isn't cost-effective. Full line replacement with corrosion-protected tubing is the smarter investment.